beautypg.com

Roland PCR-80 User Manual

Page 143

background image

143

Edit mode (EDIT)

Master Volume

F0 7F 7F 04 01 vL vM F7

Since a Master Volume message has a data range of 00 00–7F 7F and we do not need to specify the
range, we will use

Basic mode

. Since the two bytes of data are in the order of LSB and then MSB,

we will select “DT3” when we input the data.

1. Press the

[EDIT]

button.

The display will indicate “EDT”.

2. Slightly move the controller to which you want to assign the system exclusive message. In the

case of a button, press that button.
The display will indicate the number of the selected controller.

3. Confirm what’s indicated, and press the

[ENTER]

button.

4. Press the

[SYSTEM Ex.]

key.

The display will blink “SE0”.

5. Confirm what’s indicated, and press the

[ENTER]

button.

The display will indicate “F0,” which is the first byte (beginning status) of a system exclusive
message. (This cannot be changed.)

6. Confirm what’s indicated, and press the

[ENTER]

button.

7. Use the

[7]

and

[F]

keys to input the second byte “7F”.

8. Confirm what’s indicated, and press the

[ENTER]

button.

Input the third, fourth and fifth bytes in the same way.

9. Since the sixth byte is the data area, press the

[DATA]

key, and then press

[3]

.

The display will indicate “DT3”.

10. Confirm what’s indicated, and press the

[ENTER]

button.

11. Since we selected “DT3” as the sixth byte, the seventh byte will automatically be

allocated as the data area and cannot be modified.

12. Confirm what’s indicated, and press the

[ENTER]

button.

13. Use the

[F]

and

[7]

keys to input the ending status byte “F7”.

14. Confirm what’s indicated, and press the

[ENTER]

button.

15. Specify the output port. (➔

“Specifying the port”

(p. 159))

16. If you are making an assignment for a button, specify the button mode.

(➔

“Specifying the button mode”

(p. 158))

The Master Volume message has now been assigned.

This manual is related to the following products: