Specifying the port, About the ports, When using a usb – Roland PCR-80 User Manual
Page 159: Connection, P. 159), To select, refer to, About the ports when using a usb, Settings, refer to the, Software you are using, S. 159)
159
Convenient functions
Specifying the port
When you are making Assign settings (p. 41) in Edit mode and have selected Advanced mode, you
must specify the USB port to which the message assigned to the controller will be sent when using
a USB connection.
1. Press a key
[1]
–
[3]
to select the port.
2. Press the
[ENTER]
button.
*
If you are using the PCR-30/50/80 with a MIDI connection, the messages will be transmitted from the
MIDI OUT connector regardless of this port setting.
1
PORT 1
Messages will be sent to “PCR 1.”
2
PORT 2
Messages will be sent to “PCR 2.”
3
PORT 1,2
Messages will be sent to both “PCR 1” and “PCR 2.”
About the ports when using a USB connection
The ports correspond to the PCR-30/50/80 as follows.
fig.pcr-port
MIDI OUT device
PCR MIDI OUT
(
Mac OS 9/8 : PCR MIDI IN, OUT)
If you specify
PCR MIDI OUT
as the output port for your sequencer software, the
MIDI messages will be sent from the MIDI OUT connector of the PCR-30/50/80.
PCR
(Mac OS 9/8 : PCR 1)
This is the Bulk reception port. When receiving bulk data into the PCR-30/50/80,
specify
PCR
as the output port for your sequencer software.
MIDI IN device
PCR MIDI IN
(
Mac OS 9/8 : PCR MIDI IN, OUT)
If you specify
PCR MIDI IN
as the input port for your sequencer software, MIDI
messages from the MIDI IN connector of the PCR-30/50/80 can be received.
PCR 1
PCR 2
This is the port at which messages from the keyboard, BENDER lever, and control-
lers will be input.
The keyboard, BENDER lever, and controllers will be mapped to
PCR 1
and/or
PCR 2
according to the port setting.
You may find it convenient to specify
PCR 1
for messages used to play a software
synthesizer or for realtime recording on a sequencer track, and specify
PCR 2
for
messages used to control the sequencer, such as sequencer play/stop or track fader
control.
PCR 2
is the bulk transmission port. When transmitting bulk data from the
PCR-30/50/80, specify
PCR 2
as the input port for your sequencer software.
PCR-30/50
PCR-30/50 USB Driver
USB
Bulk reception
EDIROL PCR
EDIROL PCR MIDI OUT
EDIROL PCR 2
EDIROL PCR 1
PORT 1
EDIROL PCR MIDI IN
MIDI OUT device (port name)
MIDI IN device (port name)
PORT 2 /
Bulk transmission
* As seen from the PCR-30/50/80, each
section of the diagram does the following.
PORT 1
Of the keyboard, bender level, and
controllers, those assigned to PORT 1
are transmitted from here
PORT 2
Of the keyboard, bender level, and
controllers, those assigned to PORT 2
are transmitted from here
Bulk transmission
This section transmits bulk data
Bulk reception
This section receives bulk data