Ethernet ports, Rj45 twisted-pair data ports, Console port on display board – RuggedCom RUGGEDSWITCH RSG2288 User Manual
Page 22: 22 3.23. rs2000 series console cable, Rs232 over rj45 console cable pin-out, Figure 3.22, “console port on display board, Figure 3.23, “rs2000 series console, Cable

3. Installation
RuggedCom® RuggedSwitch®
22
RSG2288 Installation Guide Rev 108
Figure 3.22. Console Port on Display Board
Figure 3.23. RS2000 Series Console Cable
Signal Name (PC is DTE)
DB9- Female
RJ45 Male
DCD – Carrier detect
1
2
RxD – Receive data (to DTE)
2
5
TxD – Transmit data (from DTE)
3
6
DTR – Data terminal ready
4
3
GND - Signal ground
5
4
DSR – Data set ready
6
1*
RTS – Ready to send
7
8
CTS – Clear to send
8
7
RI – Ring Indicator
9
1*
Table 3.2. RS232 Over RJ45 Console Cable Pin-out
After initial configuration, the RSG2288 can be configured via a number of networked mechanisms
such as Telnet SSH, and the built-in secure web server. Consult the ROS™ User Guide for further
details.
• This port is not intended to be a permanent connection.
• Serial cable must not exceed 2m (6.5 ft) in length.
3.2.7. Ethernet Ports
3.2.7.1. RJ45 Twisted-Pair Data Ports
RS2000 series Ethernet switches are equipped with up to nine 10/100/1000BaseTX ports
that allow connection to standard CAT-5 UTP cable with RJ45 male connectors. All RS2000
series RJ45 RuggedSwitch® products feature auto-negotiation, auto-polarity, and auto-crossover
functions. The RJ45 receptacles can also accept and take advantage of screened (commonly
known as “shielded”) cabling. The figure below shows the RJ45 port pins configuration.