M3062PT3-RPD-E User’s Manual

3. Usage (How to Use the Emulator Debugger)

REJ10J0040-0600 Rev.6.00 July 01, 2006

Page 65 of 104


(3) When DATA ACCESS is selected

1) Window for setting the address

Setting the address

Sets the address by “Address” tab.
You can set eight conditions, e.g., a specified address, a specified address
range, etc.
When you have finished setting the address, set the data.


2) Window for setting data

Setting data

Sets the address by “Data” tab.
You can set eight conditions, e.g., specified data, specified data range, etc.

Setting the access condition

You can set three conditions, e.g., read, write, and read/write. When you
have finished setting the data and access condition, click OK.