beautypg.com

Caution, Important – Renesas Emulation Pod M3062PT3-RPD-E User Manual

Page 35

background image

M3062PT3-RPD-E User’s Manual

2. Setup

REJ10J0040-0600 Rev.6.00 July 01, 2006

Page 35 of 104



2.8.5 Connecting to a 100-pin 0.65mm Pitch Foot Pattern (Part 3)
Figure 2.13 shows how to connect a 100-pin 0.65mm pitch foot pattern on the user system to the M3T-DUMMY100S (not
included), and here following is its procedure. For details on the M3T-100LCC-DMS (not included) and M3T-DUMMY100S
(not included), refer to each user's manual.

(1) Attach the M3T-DUMMY100S to the user system.
(2) Attach the M3T-100LCC-DMS to the M3T-DUMMY100S.
(3) Attach the CN2 side of the M30800T-PTC to the CN2 side of the package converter board connected to the emulation pod

probe.

(4) Attach the M30800T-PTC to the M3T-100LCC-DMS.

Figure 2.13 Connecting to a 100-pin 0.65mm pitch foot pattern (3/3)

CAUTION

Note on Connecting the User System:

z

Take care not to attach the converter board in a wrong direction. It may cause a fatal damage to the emulation

pod.

IMPORTANT

Notes on Connectors of the Converter board:

z

The connectors of the M30800T-PTC are guaranteed for only 50 insertion/removal iterations.

z

The connectors of the M3T-100LCC-DMS and M3T-DUMMY100S are guaranteed for only 20

insertion/removal iterations.

M3T-100LCC-DMS

(not included)

CN2 side

(3)

(4)

M30800T-PTC

(2)

FLASH MCU, etc.

On-board evaluation

M3T-DUMMY100S

(not included)

(1)

100-pin 0.65mm pitch

(PRQP0100JB-A) foot pattern

No. 1 pin

User system

Package converter board

Tip of emulation pod probe