2.7 Self-check

2.7.1 Self-check Procedure
To run the self-check of the emulator, do so as explained here below. While the self-check is in progress, the LEDs will change
as shown in Figure 2.6.

(1) If the user system is connected, disconnect it.
(2) Set the switches in the emulation pod to the factory settings as shown in Figure 2.7.
(3) Within 2 seconds of activating power to the emulator, press the system reset switch on the emulator front panel to switch

the emulator to maintenance mode.

(4) Check the SAFE LED starts blinking and then press the system reset switch again.
(5) The self-check will start. If the normal result is displayed in about 30 seconds, the self-check has terminated normally.

Figure 2.6 LED display in the self-check procedure

Immediately after turning on the power

P OWE R

SAFE

ERROR

S T A T U S O F

S YS TEM

RESET

P OWE R

C LOCK

RESE T

RUN

HAL T

P OWE R

SAF E

ERROR

S TA TUS OF

SYSTEM

RESET

POWE R

CL OCK

RE S E T

RU N

HA L T

P O WE R

SA F E

ER ROR

S T A T US OF

SYSTEM

RESET

P OWER

C LOC K

RES E T

RUN

HAL T

P OWE R

S A F E

E R R OR

S TA TU S OF

SYSTEM

RESET

P OWE R

C L O CK

R E S E T

RUN

HA L T

POWE R

SA F E

ERR OR

S TA TU S OF

SYSTEM

RESET

P OWE R

CL OCK

RE S ET

RU N

HA L T

(1) All the LEDs light

Completed normally

: Blinking

: On
: Off

Self - check

Target status error

System status error

(2) SAFE LED blinks

ERROR LED lights

SAFE and ERROR LED blink