2. Setup

REJ10J0040-0600 Rev.6.00 July 01, 2006

Page 31 of 104



2.8.1 Connecting to a 80-pin 0.65mm Pitch Foot Pattern
Figure 2.9 shows how to connect 80-pin 0.65mm pitch foot pattern on the user system to the M3062PT-80FPB (not included),
and here following is its procedure.
For details on the M3062PT-80FPB (not included), refer to its user's manual.

(1) Attach the NQPACK080SB included with the M3062PT-80FPB to the user system.
(2) Attach the YQPACK080SB included with the M3062PT-80FPB to the NQPACK080SB and secure it with the

YQ-GUIDE's.

(3) Attach the CN2 side of the M3062PT-80FPB to the CN2 side of the package converter board connected to the emulation

pod probe.

(4) Attach the M3062PT-80FPB to the YQPACK080SB.

*

CN2 side

(3)

(1)

80-pin 0.65mm pitch

(PRQP 0080JA -A) foot pattern

No. 1 pin

User system

M3062PT- 80 FPB (not included)

FLASH MCU, etc.

On-board evaluation

*: These four items are included in one package.

YQPACK080 SB

NQPACK080 SB

HQPACK 080SB

(2)

(4)

YQ-GUIDE (x 4)

These corners are not round.

Package converter board

Tip of emulation
pod probe

(not included)

Figure 2.9 Connecting to a 80-pin 0.65mm pitch foot pattern

CAUTION

Note on Connecting the User System:

z

Take care not to attach the converter board in a wrong direction. It may cause a fatal damage to the emulation

pod.

IMPORTANT

Note on Connectors of the Converter board:

z

The small connectors of the M3062PT-80FPB are guaranteed for only 50 insertion/removal iterations.