P. 74) – Roland TD-6 User Manual
Page 74
74
Chapter 2 Making the Pad and Trigger Settings (SETUP/TRIG)
SPLINE:
Extreme changes are made in response to the force used to
strike the pad.
fig.02-013.e
LOUD1, LOUD2:
Changes made in response to the striking force are minor,
maintaining a volume level at which it is easy to play. When
using drum triggers, these settings help maintain stable levels.
fig.02-014.e (LOUD)
Eliminate Crosstalk Between Pads
(Crosstalk Cancel)
When two pads are mounted on the same stand, the vibration
produced by hitting one pad may trigger the sound from
another pad unintentionally (This is called
crosstalk
.) You
can avoid this problem by adjusting Crosstalk Cancel on the
pad that is sounding inadvertently.
If the value is set too high, then when two pads are played
simultaneously, the one that is struck less forcefully will not
sound. So be careful and set this parameter to the minimum
value required to prevent such crosstalk. With a setting of
“OFF,” crosstalk prevention does not function.
In some cases, you can prevent crosstalk between two pads
you have connected by increasing the distance between the
pads.
Example:
When hitting a snare pad, the hi-hat cymbal also
sounds
Set the “Xtalk Cancel (Crosstalk Cancel) for the pad being
used for the hi-hat while striking the snare pad. Striking the
snare pad, raise the “CROSSTALK” setting for the hi-hat
cymbal pad from “OFF” through “20,” “25.”.. until crosstalk
no longer occurs. As this value is raised, the hi-hat cymbal pad
will be less prone to receive crosstalk from other pads.
The pad’s settings screen is not switched when “Note Chase” is
set to “OFF” (SETUP/MIDI COMMON/Note Chase; p. 59, p. 98).
fig.02-025_50
Xtalk Cancel (Crosstalk Cancel):
OFF, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65,
70, 75, 80
Fine-Tuning the Trigger
Parameter Settings
(TRIGGER ADVANCED)
The following parameters (Advanced Trigger Parameters) are
automatically set to the most efficient values for each pad
when you select the TRIGGER TYPE (SETUP/TRIG BASIC/
TrigTyp; p. 71), and don’t require adjustment, except if you
experience any of the problems that are discussed below.
1.
While holding down [SHIFT], press [EDIT (SETUP)].
[EDIT] lights.
2.
Press [
] to select “TRIG ADVNCD.”
fig.SETUP-ADVNCD_50 (SETUP-ADVNCD)
3.
Press [ENTER
].
4.
Press [
] or [
] to select the parameter you
wish to edit.
fig.02-017ai.e
5.
Strike the pad you wish to set.
The settings screen for the struck pad appears, and the
input indicator fluctuates.
6.
Press [INC/+] or [DEC/-] to make the setting.
fig.02-018ai.e
7.
When you finish making settings, press [KIT] or
[SONG] to end the procedure.
Volume
Striking Force
SPLINE
Volume
Volume
Striking Force
LOUD2
LOUD1
Parameter to set
Value