beautypg.com

Maintenance, Removing valve, Removing the fan – Regency P42-NG4 User Manual

Page 38: Replacing the fan

background image

Regency

®

P42-4 Zero Clearance Direct Vent Gas Fireplace

38

REMOVING VALVE

1) Shut off the gas supply.

2) Remove the louvers (and bay door if it is

on).

3) Disconnect the inlet gas line.

Note: Be sure to have an 11/16" wrench on

the tee to ensure that the whole line
is not twisted

4) Disconnect the 2 TP wires and the 2 TH

wires from the valve.

5) Remove the Piezo igniter wire.

6) Open and remove the fl ush door.

7) Remove the logs.

8) Remove the burner tube by removing the 3

Phillips head screws and then lift the burner
out.

9) Remove the burner grate assembly by

removing the 3 Phillips head screws on the
feet of the grate assembly.

10) Brush away all the vermiculite and embers

from the right hand half of the fi replace.

11) Remove the top and right hand side brick

panels.

12) Remove the 12 Phillips head screws securing

the valve access plate in place and then lift
the entire assembly out.

13) Undo the pilot tube from the valve with a
7/16"

wrench.

14) Undo the quick drop out thermocouple nut

on the valve with a 9mm wrench.

15) Undo the "gas out" fl are nut with a 13/16"

wrench.

16) Undo the "gas out" 90

o

elbow fl are fi tting with

an 11/16" wrench.

17) Remove the 4 Phillips head screws from

the sides of the valve bracket and remove
valve.

Hint: If you are using black pipe, ensure
that there is a union by the valve, otherwise
removal will be almost impossible.

Grounding lug detail

REMOVING THE FAN

1) Shut the power off.

2) Remove the bottom louver.

3) Remove terminal block cover and disconnect

the fan wires.

4) Disconnect white fan wire from the terminal

block.

5) Disconnect black fan wire from the

thermodisc.

6) Disconnect

fan

ground

wire.

7) Lift the fan off the two mounting studs and

pull out.

IMPORTANT:
These fans collect a lot of dust
from within your home. Ensure
you maintain these fan motors on
a regular basis by vacuuming out
the fan squirrel cages.

REPLACING THE FAN

1) Shut the power off.

2) Remove the bottom louver. Slide the fan in

and push it towards the rear of the unit and
slip it over the two mounting studs.

3) Remove the terminal block cover. Wire the

fan to the terminal block as shown in the
wiring diagram below.

4) Connect white wire from fan to neutral of

terminal block.

5) Connect black wire from fan to the

thermodisc.

6) Connect fan ground wire. Refer to wiring

diagram.

7) Attach the ground wire to the fi replace

(ground lug provided).

8) Attach the terminal block cover.

Note: A 120 Volt AC power cord should be

installed at rough-in stage so that
the power is available. A three wire
power cord can be used.

The bearings are lubricated for life.
Do not lubricate them. Make sure
you vacuum the fan area on a regular
basis.

MAINTENANCE