P42-4 Zero Clearance Direct Vent Gas Fireplace

16

INSTALLATION

RIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS

REGENCY

®

DIRECT VENT SYSTEM (FLEX)

- Propane & Natural Gas

The diagram below shows examples of horizontal termination arrangements using two 90

o

elbows.

If length "B" is increased, length "A" must be decreased by a corresponding amount.

Note:

1) A maximum of two 90

o

elbows are permitted (two 45

o

elbows equal one 90

o

elbow).

2) A minimum of 6 ft.(1.8m) vertical from base of unit is required if two 90

o

elbows are used.

3) Minimum distance between elbows is 2 ft. (0.6m).

Maintain a 1-1/4" clearance to

combustibles for rigid pipe systems
and 1-1/2" for Regency

®

Flex Vent.

• Horizontal vent must be supported

every 3 feet

• Firestops are required at each fl oor

level and whenever passing through
a wall.

All Rigid Pipe Systems
4" inner diameter
6-5/8" outer diameter

Regency

®

Flex Vent

4" inner diameter
6-7/8" outer diameter

A vent guard may be required, check local codes.

Note: Regency

®

Direct Vent System (Flex) is only

approved for horizontal terminations.

For All Horizontal Terminations