Installation, Rigid pipe venting, Horizontal or vertical terminations – Regency P42-NG4 User Manual

Page 14

background image

Regency

®

P42-4 Zero Clearance Direct Vent Gas Fireplace

14

Rigid Pipe Adaptor

(Part# 510-994)

Pipe Length

Vertical

Terminal

Storm Collar

Part # 953

Flashing

943 or 943S

Ceiling Firestop

(Part # 963)

24" Pipe

Length

Adj.Pipe Length

11" - 14-5/8"

90 Elbow

o

Horizontal

Termination

Cap

Wall Thimble

Part # 942

Vinyl Siding

Standoff (Optional)

Part #950

RIGID PIPE VENTING

Horizontal or Vertical Terminations

The Rigid Pipe Venting System offers a complete line of component parts for installation of both horizontal and vertical installations. Many items are
offered in decorative black, as well as galvanized fi nish. We recommend using the galvanized fi nish for installation with the P42.

The minimum components required for a basic
horizontal termination are:

1 Horizontal

Termination

Cap

1 90

o

Elbow

1 Flue

Adaptor

1 Wall

Thimble

1 Length of pipe to suit wall thickness
(see

chart)

Alternate

Horizontal

Termination Caps

INSTALLATION

Flat Wall Installation

Wall Thickness Vent Length

(inches) Required (inches)

4"

-

5-1/2"

6"

7"

-

8-1/2"

9"

10"

-

11-1/2"

12"

9"

-

14-1/2" 11" - 14-5/8" Adj. Pipe

15"

-

23-1/2"

17" - 24" Adj. Pipe

Corner Installation

Wall Thickness Vent Length
(inches) Required (inches)
3-1/4"

-

6-3/4"11" - 14-5/8" Adj. Pipe

7-3/4"

-

16-1/4"

17" - 24" Adj. Pipe

7-1/4"

-

8-3/4"

6" + 12"

9"

+

9"

4-1/4"

-

5-3/4"

6" + 9"

Wall thickness is measured from the back
standoffs to the inside mounting surface of
termination cap. For siding other than vinyl
furring strips may be used, instead of the vinyl
siding standoff, to create a level surface to
mount the vent terminal. The Terminal must
not be recessed into siding. Measure the wall
thickness including furring strips.

If a Vinyl Siding Standoff is required (it must
be used with vinyl siding), measure to outside
surface of wall without siding and add 2
inches.

When using Rigid Vent other than

Simpson Dura-Vent, 3 screws must be

used to secure rigid pipe to adaptor.

The FPI AstroCap

TM

and FPI Riser Vent terminal are certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent

®

Direct Vent GS,

American Metal Products Ameri Vent Direct Vent, Security Secure Vent

®

, Selkirk Direct-Temp. AstroCap

TM

is a proprietary trademark of FPI Fireplace

Products International Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.

This product has been evaluated by Intertek for
using a Rigid Pipe Adaptor in conjunction with
Duravent Direct-Vent GS, Selkirk Direct-Temp,
Ameri Vent Direct venting and Security Secure
Vent systems. Use of these systems with the
Rigid Pipe adaptor is deemed acceptable
and does not affect the Intertek WHI listing of
components.

WARNING:

Do not combine venting components from
different venting systems.

However use of the the AstroCap

TM

and FPI

Riser is acceptable with all systems.