P42-4 Zero Clearance Direct Vent Gas Fireplace

34

OPTIONAL

WALL THERMOSTAT

A wall thermostat may be installed if desired,
connect the wires as per the wiring diagram.
Use table below to determine the maximum
wire length.

Note: Preferable if the thermostat is

installed on an interior wall.

Regency

®

offers an optional programmable

thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or
UL approved may be used.

CAUTION

Do not wire millivolt

wall thermostat wires

to 120V wire.

OPERATING

INSTRUCTIONS

1) Read and understand these instructions

before operating this appliance.

2) Check to see that all wiring is correct and

enclosed to prevent possible shock.

3) Check to ensure there are no gas leaks.

4) Make sure the glass in the door frame is

properly positioned. Never operate the
appliance with the glass removed or with
broken glass.

5) Verify that the venting and cap are

unobstructed.

6) Ensure that the brick panels are installed.

7) Verify log placement. If the pilot cannot be

seen when lighting the unit, the logs have
been incorrectly positioned.

8) The unit should never be turned off, and on

again without a minimum of a 60 second
wait.

OPERATING INSTRUCTIONS

LIGHTING

PROCEDURE

NOTE: For all propane units and units

equipped with electric spark boxes,
see "Copy of Lighting Plate Instruc-
tions" section for more details.

IMPORTANT: Gas on/off knob cannot be
turned from "PILOT" to "OFF" unless it is
partially depressed.

OPTIONAL

REMOTE CONTROL

Use the Regency

®

Remote Control Kit approved

for this unit. Use of other systems may void
your warranty.

The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.

1) Choose a convenient location on the wall

to install the receiver and the receptacle
box (protection from extreme heat is very
important). Run wires from the fi replace to
that location. Use Thermostat Wire Table.

2) Connect the two wires to the gas valve. See

diagram below.

CAUTION

Do not wire millivolt

remote control wires

to 120V wire.

3) Install 3 AAA alkaline batteries in transmitter

and 4 AA alkaline batteries in the receiver.
Install the receiver and its cover in the wall.
Switch the remote receiver to "remote"
mode. The remote control is now ready for
operation.

Optional

WALL SWITCH

1) Run the supplied 15' of wire through the right

or left side gas inlet opening. Be careful not
to damage wire.

Note: We recommend a maximum of 15'

of wire but if you wish to go with a
longer run, use the Thermostat Wire
Table.

2) Connect the wire to the supplied wall switch

and install into the receptacle box.

CAUTION

Do not wire millivolt

wall switch wire

to 120V wire.

14 GA.
16 GA.
18 GA.
20 GA.
22 GA.

50 Ft.
32 Ft.
20 Ft.
12 Ft.

9 Ft.

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size Max. Length

Thermostat Wire Table

IMPORTANT

To ignite or reignite the pilot,

you must fi rst release the

tension springs below the door.