beautypg.com

Maintenance, Shutdown procedure, First fire – Regency P42-NG4 User Manual

Page 36: Normal operating sounds of gas appliances, Maintenance instructions

background image

Regency

®

P42-4 Zero Clearance Direct Vent Gas Fireplace

36

1) Push in gas control knob slightly and turn

clockwise to "OFF". Knob cannot be turned

from "PILOT" to "OFF" unless knob is pushed

in slightly. Do not force.

2) Wait 5 minutes to clear out any gas.

3) Turn knob on gas control countercloskwise

to "PILOT".

4) Push in control knob all the way and hold

in. Immediately push black button on spark

igniter until pilot lights. Continue to hold the

control knob in for about 1/2 minute after

the pilot light is lit. Release knob and it will

pop back up. Pilot should remain lit.

5) Turn gas control knob counterclockwise to

"ON".

6) Use rocker switch to operate main burner.

SHUTDOWN

PROCEDURE

1) Use the wall switch, thermostat or remote

control to turn off the main burner.

2) Turn the main gas control clockwise to the

"OFF" position to turn off the pilot.

3) Turn off all electric power to appliance if

service is to be performed.

FIRST FIRE

The fi rst fi re in your fi replace is part of the
paint curing process. To ensure that the paint
is properly cured, it is recommended that you
burn your fi replace for at least four (4) hours the
fi rst time you use it with the fan on. When fi rst
operated, the unit will release an odour caused
by the curing of the paint, the burning off of
any oils remaining from manufacturing. Smoke
detectors in the house may go off at this time.
Open a few windows to ventilate the room for
a couple of hours.

The glass panel may require cleaning after the

unit has cooled down.

DO NOT ATTEMPT TO CLEAN THE
GLASS WHILE IT IS HOT.

During the fi rst few fi res, a white fi lm
may develop on the glass front as part
of the curing process. The glass should
be cleaned or the fi lm will bake on and
become very diffi cult to remove. Use a
non-abrasive cleaner and NEVER clean
the glass while it is hot.

Note: When the glass is cold and the

appliance is lit, it may cause
condensation and fog the glass.
This condensation is normal and will
disappear in a few minutes as the
glass heats up.

DO NOT BURN THE APPLIANCE

WITHOUT THE GLASS FRONT IN

NORMAL OPERATING

SOUNDS OF

GAS APPLIANCES

It is possible that you will hear some sounds
from your gas appliance. This is perfectly normal
due to the fact that there are various gauges
and types of steel used within your appliance.
Listed below are some examples. All are normal
operating sounds
and should not be considered
as defects in your appliance.

Blower:
Regency

®

gas appliances use high tech blowers

to push heated air farther into the room. It is not
unusual for the fan to make a "whirring" sound
when ON. This sound will increase or decrease
in volume depending on the speed setting of
your fan speed control.

Burner Tray:
The burner tray is positioned directly under the
burner tube and logs and is made of a different
gauge material from the rest of the fi rebox and
body. Therefore, the varying thicknesses of steel
will expand and contract at slightly different
rates which can cause "ticking" and "cracking"
sounds. You should also be aware that as there
are temperature changes within the unit these
sounds will likely re-occur. Again, this is normal
for steel fi reboxes.

Blower Thermodisc:
When this thermally activated switch turns ON
it will create a small "clicking" sound. This is the
switch contacts closing and is normal.

Pilot Flame:
While the pilot fl ame is on it can make a very
slight "whisper" sound.

Gas Control Valve:
As the gas control valve turns ON and OFF, a
dull clicking sound may be audible, this is normal
operation of a gas regulator or valve.

MAINTENANCE

MAINTENANCE

INSTRUCTIONS

1) Always turn off the gas valve before cleaning.

For relighting, refer to lighting instructions.
Keep the burner and control compartment
clean by brushing and vacuuming at least
once a year. When cleaning the logs, use a
soft clean paint brush as the logs are fragile
and easily damaged.

2) Clean appliance and door with a damp

cloth (never when unit is hot). Never use
an abrasive cleaner. The glass should be
cleaned with a gas fi replace glass cleaner.
The glass should be cleaned when it
starts looking cloudy.

3) The heater is fi nished in a heat resistant

paint and should only be refi nished with heat
resistant paint. Regency

®

uses StoveBright

Paint - Metallic Black #6309.

4) Make a periodic check of burner for proper

position and condition. Visually check the
fl ame of the burner periodically, making sure
the fl ames are steady; not lifting or fl oating. If
there is a problem, call an authorized service
person.

5) The appliance and venting system must be

inspected before use, and at least annually,
by an authorized fi eld service person, to
ensure that the fl ow of combustion and
ventilation air is not obstructed.

6) Verify proper operation after servicing.

Note:

Never operate the appliance without
the glass properly secured in
place.

Unit Body/Firebox:
Different types and thicknesses of steel will
expand and contract at different rates resulting
in some "cracking" and "ticking" sounds will be
heard throughout the cycling process.

This manual is related to the following products: