Regency

®

P42-4 Zero Clearance Direct Vent Gas Fireplace

11

6-7/8"

(173mm) dia.

Flue pipe

4" (102mm)
dia. flue pipe

Termination Cap
Part #946-523/P

AstroCap

spring
spacer

Wall Thimble (2 pc)

INSTALLATION

VENTING

Regency

®

Direct Vent System (Flex) Horizontal Terminations Only

These venting systems, in combination with the P42 Direct Vent Gas
Fireplace, have been tested and listed as a direct vent heater system
by Warnock Hersey. The location of the termination cap must conform to
the requirements in the Vent Terminal Locations diagram in the "Exterior
Vent Termination Locations" section.

Regency

®

Direct Vent (Flex) System Termination Kit (Part # 946-515)

includes all the parts needed to install the P42 with a maximum
run of 4 feet.

1) 6-7/8" dia. fl exible liner (4 ft. length)
2) 4" dia. fl exible liner (4 ft. length)
3) spring spacers (4)
4) thimble

(2)

5) AstroCap termination cap (1)
6) screws

(12)

7) tube of Mill Pac (1)
8) plated

screws

(8)

9) screws #8 x 1/2" Drill Point, stainless steel (4)

If longer runs are needed, the Regency

®

Direct Vent system (Flex)

# 946-516 includes all the parts needed to install the P42 with a
maximum 10' run.

1) 6-7/8" dia. fl exible liner (10 ft. length)
2) 4" dia. fl exible liner (10 ft. length)
3) spring spacers (7)
4) thimble

(2)

5) AstroCap termination cap (1)
6) screws

(12)

7) tube of Mill Pac (1)
8) plated

screws

(8)

9) screws #8 x 1/2" Drill Point, stainless steel (4)

Note:
a) Liner sections should be continuous without any joints or seams.
b) Only Flex pipe purchased from Regency

®

may be used for Flex

Installations.