P42-4 Zero Clearance Direct Vent Gas Fireplace

17

INSTALLATION

RIGID PIPE VENTING ARRANGEMENTS - VERTICAL TERMINATIONS

(Propane & Natural Gas)

Note: Must use optional rigid pipe adaptor

when using rigid vent systems (Part
# 510-994).

Note: Regency

®

Direct Vent System (Flex)

is only approved for horizontal
terminations.

The shaded area in the diagram shows all allowable combinations of straight vertical and offset
to vertical terminations with rigid pipe vent systems for Propane and Natural Gas.

Maximum two 45

o

elbows allowed.

• Vent restrictor #6 must be used in shaded area in diagram below.
• Vent must be supported at offsets

The P42 is approved for a 37 ft. (11.3m) straight
vertical, including a 20" (0.5m) horizontal offset
using two 90

o

elbow (two 45

o

elbows equal one

90

o

elbow) with rigid pipe vent systems for

Propane and Natural Gas, as per the diagram
to the right.

• Vent restrictor #6 is required for

terminations in shaded area.

• Vent must be supported at offsets.

Diagram 1

Diagram 2