Safety system, Filter system, Optional basket lift – Pitco Frialator Gas Fryers SG Serie User Manual
Page 8
Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers
L22‐345 R1
8
Safety System
When the roll out switch or hi-limit trips, it interrupts the 24 VAC supply to the ignition module.
When the controller calls for heat, it does not receive a 24 VAC HFB. With approximately 90 seconds of
HFB loss, the controller indicates an ignition failure or heat failure.
After the roll out switch hi-limit is reset, turn the controller off and then back on for the unit to heat.
Filter System
Opening the RED return valve handle:
Opens the return valve to that vat.
Closes the pump proximity switch causing the “pump run” relay to be energized.
The pump motor begins to run.
Closing the return valve handle de-energizes the relay and the pump motor stops running and the return valve
closes.
The pump system is equipped with a circuit breaker which de-energizes the system and the heat tape in the
event of over current. The circuit breaker must be in the “ON” position for the pump and heat tape to operate.
NOTE: Circuit Breaker should remain in the “ON” position at all times.
The return piping system may be provided with optional heat tape to prevent solidification of solid
shortening. The heat tape is low wattage and is on constantly to maintain liquid shortening in the line.
Optional Basket Lift
The basket lift is a self contained unit that requires a 120V, 208V, or 240V supply. With most fryer
configurations, the power is supplied from the entrance box at the back of the fryer, but some configurations
require power directly from a wall outlet.
When power is supplied to basket lift assembly, the baskets lift to the up position.
The baskets lower with a 24 VDC output from the controller.
The basket lift control voltage is supplied from the controller
The basket lift operational voltage is supplied from the line voltage supply that powers the transformer in the
basket lift assembly.