Accessing Fryer for Servicing 

1. Shut off the main gas supply line.

2. Shut off the individual gas supply line.

Cleaning the Gas Valve Vent Tube 

See “Cleaning the Gas Valve Vent Tube” on page 13.

Checking the Burner Manifold Gas Pressure 

Taking an Incoming Supply Gas Pressure Reading

1. Unscrew and remove the gas supply plug with a

3/16 inch hex wrench.

2. Finger tighten the test fitting into the test port.

3. Finish tightening the test fitting using a 7/16

inch open-ended wrench.

4. Connect the manometer.

5. Turn on the main gas supply line.