Accessing fryer for servicing, Cleaning the gas valve vent tube, Checking the burner manifold gas pressure – Pitco Frialator Gas Fryers SG Serie User Manual
Page 51: Taking an incoming supply gas pressure reading

Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers
L22‐345 R1
51
Accessing Fryer for Servicing
1. Shut off the main gas supply line.
2. Shut off the individual gas supply line.
Cleaning the Gas Valve Vent Tube
See “Cleaning the Gas Valve Vent Tube” on page 13.
Checking the Burner Manifold Gas Pressure
Taking an Incoming Supply Gas Pressure Reading
1. Unscrew and remove the gas supply plug with a
3/16 inch hex wrench.
2. Finger tighten the test fitting into the test port.
3. Finish tightening the test fitting using a 7/16
inch open-ended wrench.
4. Connect the manometer.
5. Turn on the main gas supply line.