Measuring Thermopile
Taking a Millivolt Reading
1. Make sure the multimeter is set to mV.
2. Touch the thermopile leads with the multimeter
probes as shown.
Adjusting the Thermopile
1. Compare the multimeter reading to the
Thermopile mV table.
Thermopile mV Table
Pilot lit
Pilot lit with burners on
PP1 to PP2
600± mV
PP2 to TH2 approximately
300 mV less than pilot alone
2. Insert a flathead screwdriver into the Pilot Adj.
cap and turn counter-clockwise to remove it.
mV Gas Valve Resistance Readings Table
Pilot Valve
Main Valve
TH 1 to PP 2 10.4 Ω TH 2 to PP 2 2.0 Ω
3. Insert flathead screwdriver into Pilot Adj. screw
and turn counter-clockwise to increase the mV
pressure or clockwise to decrease the mV
pressure.
4. Disconnect the multimeter.