Adjusting manifold gas pressure – Pitco Frialator Gas Fryers SG Serie User Manual
Page 53

Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers
L22‐345 R1
53
Adjusting Manifold Gas Pressure
1. Check the manifold gas pressure with the
manometer and compare the reading to the
Manifold Gas Pressure table.
Manifold Gas Pressure Table
NAT LP
4.0” 10”
2. Insert a flathead screwdriver into the cap and
turn counter-clockwise to remove it.
3. Insert flathead screwdriver into cap and turn
counter-clockwise to increase the gas pressure or
clockwise to decrease the gas pressure.
4. When adjustment is complete:
a. Shut off the gas supply line.
b. Disconnect manometer.
c. Remove the test fitting.
d. Reinstall the gas manifold plug.
e. Turn on gas supply line.
This manual is related to the following products: