beautypg.com

Taking a manifold gas pressure reading – Pitco Frialator Gas Fryers SG Serie User Manual

Page 52

background image

Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers 
 
 

 
L22‐345 R1 

52 

6. Check the supply gas pressure with the

manometer and compare the reading to the

Supply Gas Pressure table on page 52 to

determine what the incoming gas pressure

should be.

Supply Pressure Table 

NAT LP

7 to 9

11 to 13

NOTE: You cannot adjust the supply gas

pressure at the unit. Anything
over/under the recommended
amount should be adjusted at the
facility’s main gas line.

7. When adjustment is complete:

a. Shut off the main gas supply line
b. Disconnect manometer.
c. Remove the test fitting.
d. Apply Fluropolymer paste to gas supply

plug.

e. Reinstall gas supply plug with a 3/16 inch

hex wrench.

f. Turn on the main gas supply line.

Taking a Manifold Gas Pressure Reading

1. Unscrew and remove the gas manifold plug with

a 3/16 inch hex wrench.

2. Finger tighten the test fitting into the test port

3. Finish tightening the test fitting using a

7/16 inch open-ended wrench.

4. Connect the manometer.