Taking a manifold gas pressure reading – Pitco Frialator Gas Fryers SG Serie User Manual
Page 52
Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers
L22‐345 R1
52
6. Check the supply gas pressure with the
manometer and compare the reading to the
Supply Gas Pressure table on page 52 to
determine what the incoming gas pressure
should be.
Supply Pressure Table
NAT LP
7 to 9
11 to 13
NOTE: You cannot adjust the supply gas
pressure at the unit. Anything
over/under the recommended
amount should be adjusted at the
facility’s main gas line.
7. When adjustment is complete:
a. Shut off the main gas supply line
b. Disconnect manometer.
c. Remove the test fitting.
d. Apply Fluropolymer paste to gas supply
plug.
e. Reinstall gas supply plug with a 3/16 inch
hex wrench.
f. Turn on the main gas supply line.
Taking a Manifold Gas Pressure Reading
1. Unscrew and remove the gas manifold plug with
a 3/16 inch hex wrench.
2. Finger tighten the test fitting into the test port
3. Finish tightening the test fitting using a
7/16 inch open-ended wrench.
4. Connect the manometer.