Replacing the pump relay and circuit breaker, Replacing the circuit breaker – Pitco Frialator Gas Fryers SG Serie User Manual
Page 75
Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers
L22‐345 R1
75
Replacing the Pump Relay and Circuit Breaker
Replacing the Circuit Breaker
1. Disconnect the connections and power supply
cords from the filter pump.
2. Remove the pump box.
3. Remove the circuit breaker from the pump box.
4. Remove all wires on the circuit breaker using
needle-nose pliers.
5. Squeeze the tabs on the circuit breaker and push
it out.
6. Reinstall the new circuit breaker by following
steps 1 through 5 in reverse.