beautypg.com

Paxar Gold 6037EX User Manual

Page 172

background image

5-18 Programmer’s Manual

Field Description

uchEnableSuppRedun

The number of times to scan bar codes

without supplementals before

transmission. Five or more is

recommended when scanning a mix of

UPC/EAN bar codes with and without

supplementals. You must set

uchEnableSupps is set to 2 when setting

this parameter. Single digit numbers

must have a leading zero. Values are 2-

20.

Default: 7

uchXmitUPCAChkDgt

Enable/disable the requirement to

transmit UPCA bar codes with the check

digit.

Default: SCN_ENABLE

uchXmitUPCEChkDgt

Enable/disable the requirement to

transmit UPCE0 bar codes with the

check digit.

Default: SCN_ENABLE

uchXmitUPCE1ChkDgt

Enable/disable the requirement to

transmit UPCE1 bar codes with the

check digit.

Default: SCN_ENABLE

uchUPCAPreamble

Specifies how to transmit lead-in

characters for UPCA bar codes. Values

are:
0

Do not transmit

1

Transmit system character

2

Transmit system character and

country code

Default: 1