5-2 Programmer’s Manual

C O D A B A R I N F O

The CODABARINFO data structure contains scanner
configuration information about Codabar bar codes. To read
these values, applications call scnGetCodabarInfo; to set these
values, they call scnSetCodabarInfo.

typedef struct _CodabarInfo

{

unsigned char uchEnable;

unsigned char uchLength1;

unsigned char uchLength2;

unsigned char uchEnableCLSIEdit;

unsigned char uchEnableNOTISEdit;

} CODABARINFO;

Field Description

uchEnable

Enable/disable the ability to scan Codabar

bar codes.

Default: SCN_DISABLE

uchLength1

uchLength2

Specifies lengths (including start and stop

characters) for Codabar bar codes. You

can specify one or two lengths, a range of

lengths, or that any length is valid. Enter

values as follows:
Option

uchLength1 uchLength2

1 Length

Value

0

2 Lengths Higher Value Lower Value

Range

Min. Value

Max. Value

Any length 0

0

Default: 5 (uchLength1) and 55