beautypg.com

Paxar Gold 6037EX User Manual

Page 160

background image

5-6 Programmer’s Manual

Field Description

uchEnableC32Prefix

Enable/disable the ability to add “A” as a

prefix to all Code 32 bar codes. You must

enable uchCvtC39toC32 when enabling

this parameter.

Default: SCN_DISABLE

uchLength1

uchLength2

Specifies lengths (including check digits)

for Code 39 bar codes. You can specify

one or two lengths, a range of lengths, or

that any length is valid. If

uchEnableFullASCII is enabled, a range or

any length is preferred. Enter values as

follows:
Option

uchLength1 uchLength2

1 Length

Value

0

2 Lengths

High Value Low Value

Range

Min. Value Max. Value

Any length 0

0

Default: 2 (uchLength1) and 55

(uchLength2)

uchVerifyCheckDigit

Enable/disable the ability to check the

integrity of Code 39 bar codes. When this

parameter is enabled, only Code 39

symbols with a modulo 43 check digit are

decoded.

Default: SCN_DISABLE

uchXmitCheckDigit

Enable/disable the ability to transmit check

digits with the data.

Default: SCN_DISABLE

uchEnableFullASCII

Enable/disable the ability to scan Full

ASCII Code 39 bar codes. The scanner

cannot distinguish Code 39 bar codes from

Full ASCII Code 39 bar codes. Do not

enable uchEnableTrioptic and

uchEnableFullASCII at the same time.