beautypg.com

Paxar Gold 6037EX User Manual

Page 161

background image

Data Structure Reference 5-7

C O D E 9 3 I N F O

The CODE93INFO data structure contains scanner configuration
information about Code 93 bar codes. To read these values,
applications call scnGetCode93Info; to set these values, they
call scnSetCode93Info.

typedef struct _Code93Info

{

unsigned char uchEnable;

unsigned char uchLength1;

unsigned char uchLength2;

} CODE93INFO;

Field Description

uchEnable

Enable/disable the ability to scan Code 93 bar

codes.

Default: SCN_DISABLE

uchLength1

uchLength2

Specifies lengths (including check digits) for

Code 93 bar codes. You can specify one or two

lengths, a range of lengths, or that any length is

valid. Enter values as follows:
Option

uchLength1

uchLength2

1 Length

Value

0

2 Lengths

Higher Value

Lower Value

Range Min.

Value

Max. Value

Any length 0

0

Default: 4 (uchLength1) and 55 (uchLength2).