5-10 Programmer’s Manual

Field Description

uchSameSymbolTMO

The minimum time that must elapse

between scans of the same bar code (in

increments of .1 seconds). You must set

uchTriggerMode to 1 when setting this

parameter. Values are 1-99.

Default: 10

uchLinearCodeSecur

The scan security level for linear bar

codes. Values are 1-4. Select a higher

level for lower quality bar codes. See

“Scan Security Levels” for more

information.

Default: 1

uchBiDirRedun

Enable/disable the requirement to scan

bar codes in both directions (forward and

reverse).

Default: SCN_DISABLE


Scan Security Levels

The following table describes the security levels used with the
uchLinearCodeSecur parameter.

Level Number Description

1

The following bar code types (provided they meet

the specified length requirements) must be

scanned successfully twice:
Codabar

Any

length

MSI

4 characters or less

D 2 of 5

8 characters or less

I 2 of 5

8 characters or less

2

All bar code types of all lengths must be scanned

successfully twice.