beautypg.com

Security, Overview, Ati access levels – Paradyne 8784 User Manual

Page 69: Chapter 7, Chapter 7, security

background image

8784-A2-GB20-30

February 2001

7-1

7

Security

Overview

The termination unit provides several methods of security by limiting user access
to the ATI through option settings. You can:

T

Enable the Telnet Login Required option.

T

Limit the access by setting a Session Access Level option of Operator for the
Telnet Session.

T

Disable the access with the Telnet Session option.

See

Table A-5, Telnet Session Options,

in Appendix A, Configuration Options.

ATI Access Levels

The unit has two access levels: Administrator and Operator. The access level
determines what functions are accessible, as shown in

Table 7-1, Access Levels

.

Access level is also used to control access via Telnet. If the Telnet Session Access
Level is set to Administrator, a Login ID with an Operator access level is not
permitted access (see

Table A-5, Telnet Session Options,

in Appendix A,

Configuration Options).

The effective access level is the more restrictive of the session access level or the
login access level.

Table 7-1.

Access Levels

ATI Access to Menu Functions

Administrator

Operator

Status

Read-Only

Read-Only

Test

Full Access

No Access

Configuration

Full Access

Read-Only

Control

Full Access

No Access