5. Testing

5-2

February 2001

8784-A2-GB20-30

Running Network Tests

Network tests require the participation of your network service provider.

To access the Network & DSX-1 Tests screen, follow this menu selection
sequence:

Main Menu

Test

Network & DSX-1 Tests

Use the Command column to start or stop a test. When the Status column shows
that a test is Inactive, Start is displayed; when a test is Active, Stop is displayed.
Position the cursor at the desired Start or Stop command and press Enter. The
Results column displays the test duration.

When the Send and Monitor 511 test is active, ResetMon is available to reset the
error counter to zero.

Selecting Abort All Tests from the Test menu will not disrupt a Send and
Monitor 511 test.

main/test/network_DSX1 Hotwire

Slot: 4 Model: 8784

Port: 2

NETWORK & DSX-1 TESTS

Test Command Status Results

--------------------------------------------------------------------------------

Local Loopbacks

Line Loopback: Start Inactive 00:00:00

DSX-1 Repeater Loopback: Start Inactive 00:00:00

DSX-1 DTE Loopback: Start Inactive 00:00:00

Remote Loopbacks

Send Line Loopback: Down Send Inactive 00:00:00

Pattern Tests

Send and Monitor 511 Stop Active hh:mm:ss - Errors 99999+

--------------------------------------------------------------------------------

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit

ResetMon