beautypg.com

Self-test results messages, Test status messages, Table 4-2, self-test results messages – Paradyne 8784 User Manual

Page 41: Table 4-3, test status, Messages

background image

4. Monitoring the Unit

8784-A2-GB20-30

February 2001

4-5

Self-Test Results Messages

The results of the last power-on or reset self-test appear in the middle column of
the System and Test Status screen.

Test Status Messages

The Test Status messages in the following table appear in the right column of the
System and Test Status screen.

For information on testing, refer to

Chapter 5, Testing

.

Table 4-2.

Self-Test Results Messages

Message

What Message Indicates

What To Do

CPU Failed

The CPU failed internal
testing.

1. Reset the unit and try again.

2. Call your service

representative for
assistance.

Device Failed

One or more of the unit’s
integrated circuit chips has
failed device-level testing.

DSX-1 Failed, Pt n

The unit failed to internally
loop data on the DSX-1
Port n.

Failure xxxxxxxx

An internal failure occurred.
(xxxxxxxx represents an
8-digit hexadecimal failure
code for use by service
personnel.)

Record the failure code and
contact your service
representative.

Memory Failed

The unit failed memory
verification.

1. Reset the unit and try again.

2. Call your service

representative for
assistance.

Net DSL Failed, Pt n

The unit failed to loop data on
the network DSL circuit of
Port n.

Passed

No errors were detected.

No action is needed.

Table 4-3.

Test Status Messages

Test Status Message

Meaning

511 Test Active, Pt n

A 511 Test and Monitor is active on the DSL Port n network
interface.

DLB Test Active, Pt n

A Data Terminal Loopback test is active on Port n.

Lamp Test Active

The Lamp Test is active, causing the LEDs on the front panel
to light.

LLB Test Active, Pt n

A network Line Loopback test is active on Port n.

No Test Active

No tests are currently running.

RLB Test Active, Pt n

A network Repeater Loopback test is active on Port n.