Lenovo 6532 User Manual
Page 96

Table 5. DSA Preboot messages (continued)
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 7 “Parts listing, RS210 Types 6531, 6532, 6533, and 6534” on page 175 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a Trained service technician.
• Go to the Lenovo support Web site at
hints, tips, and new device drivers or to submit a request for information.
Message
number
Component Test
State
Description
Action
201-808-xxx Memory
Memory
Test
Aborted Test
canceled:
memory
controller
display/alter
buffer
execute
error.
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that the server firmware is at
the latest level. The installed firmware
level is shown in the DSA event log in the
Firmware/VPD section for this component. For
more information, see “Updating the firmware”
on page 211.
4. Run the test again.
5. If the failure remains, go to the Lenovo Web site
for more troubleshooting information at
201-809-xxx Memory
Memory
Test
Aborted Test
canceled
program
error:
operation
running fast
scrub.
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that the DSA code is at the latest
level. For the latest level of DSA code, go to
4. Make sure that the server firmware is at
the latest level. The installed firmware
level is shown in the DSA event log in the
Firmware/VPD section for this component. For
more information, see “Updating the firmware”
on page 211.
5. Run the test again.
6. If the failure remains, go to the Lenovo Web site
for more troubleshooting information at
88
Hardware Maintenance Manual