Table 5. DSA Preboot messages (continued)
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 7 “Parts listing, RS210 Types 6531, 6532, 6533, and 6534” on page 175 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a Trained service technician.
• Go to the Lenovo support Web site at
hints, tips, and new device drivers or to submit a request for information.
Message
number
Component Test
State
Description
Action
405-903-xxx BroadCom
Ethernet
Device
Test
Internal
Memory
Failed
1. Make sure that the component firmware is
at the latest level. The installed firmware
level is shown in the DSA event log in the
Firmware/VPD section for this component. For
more information, see “Updating the firmware”
on page 211.
2. Run the test again.
3. Check the interrupt assignments in the PCI
Hardware section of the DSA event log. If
the Ethernet device is sharing interrupts, if
possible, use the Setup utility see “Using the
Setup Utility” on page 197) to assign a unique
interrupt to the device.
4. Replace the component that is causing the
error. If the error is caused by an adapter,
replace the adapter. Check the PCI Information
and Network Settings information in the DSA
event log to determine the physical location of
the failing component.
5. If the failure remains, go to the Lenovo Web site
for more troubleshooting information at
98