Recovering the server firmware – Lenovo 6532 User Manual
Page 108
Table 5. DSA Preboot messages (continued)
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 7 “Parts listing, RS210 Types 6531, 6532, 6533, and 6534” on page 175 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a Trained service technician.
• Go to the Lenovo support Web site at
hints, tips, and new device drivers or to submit a request for information.
Message
number
Component Test
State
Description
Action
405-907-xxx BroadCom
Ethernet
Device
Test Loop
back at
MAC-Layer
Failed
1. Make sure that the component firmware is
at the latest level. The installed firmware
level is shown in the DSA event log in the
Firmware/VPD section for this component. For
more information, see “Updating the firmware”
on page 211.
2. Run the test again.
3. Replace the component that is causing the
error. If the error is caused by an adapter,
replace the adapter. Check the PCI Information
and Network Settings information in the DSA
event log to determine the physical location of
the failing component.
4. If the failure remains, go to the Lenovo Web site
for more troubleshooting information at
405-908-xxx BroadCom
Ethernet
Device
Test LEDs
Failed
1. Make sure that the component firmware is
at the latest level. The installed firmware
level is shown in the DSA event log in the
Firmware/VPD section for this component. For
more information, see “Updating the firmware”
on page 211.
2. Run the test again.
3. Replace the component that is causing the
error. If the error is caused by an adapter,
replace the adapter. Check the PCI Information
and Network Settings information in the DSA
event log to determine the physical location of
the failing component.
4. If the failure remains, go to the Lenovo Web site
for more troubleshooting information at
Recovering the server firmware
Important: Some cluster solutions require specific code levels or coordinated code updates. If the device
is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before
you update the code.
If the server firmware has become corrupted, such as from a power failure during an update, you can
recover the server firmware in one of two ways:
100
Hardware Maintenance Manual