beautypg.com

System-board leds – Lenovo 6532 User Manual

Page 120

background image

Table 6. System board jumpers (continued)

Jumper number

Jumper name

Jumper setting

Notes:

1. If no jumper is present, the server responds as if the pins are set to 1 and 2.

2. Changing the position of the UEFI boot recovery jumper from pins 1 and 2 to pins 2 and 3 before the server is

turned on alters which flash ROM page is loaded. Do not change the jumper pin position after the server is
turned on. This can cause an unpredictable problem.

Important:

1. Before you change any switch settings or move any jumpers, turn off the server; then, disconnect all

power cords and external cables. Review the information in “Guidelines for trained service technicians”
on page 115
, “Handling static-sensitive devices” on page 117, and “Turning off the server” on page 113.

2. Any system-board switch or jumper blocks that are not shown in the illustrations in this document

are reserved.

System-board LEDs

The following illustration shows the light-emitting diodes (LEDs) on the system board.

Heatsink

Orientation

DIMMs

DIMMs

1

Fan 5 error LED

9

PCI Express slot 2 error LED

2

Fan 4 error LED

10

PCI Express slot 1 error LED

3

H8 Heartbeat LED

11

Microprocessor error LED

4

Fan 3 error LED

12

Battery error LED

5

Fan 2 error LED

13

Standby power LED

6

Fan 1 error LED

14

System board error LED

112

Hardware Maintenance Manual

This manual is related to the following products: