beautypg.com

Completing the fru replacement – Lenovo 6532 User Manual

Page 180

background image

corresponding mapping layer. To see the Advanced Settings Utility Users Guide. You can access the
ASU Users Guide from the Lenovo support Web site.

a. Go to http://www.lenovo.com/support.

b. Enter your product number (machine type and model number) or select Servers and Storage

from the Select your product list.

c. From Family list, select ThinkServer RS210;, and click Continue.

d. Click Downloads and drivers.

e. Click User's guides and manuals to link to the ASU Users Guide.

The following commands are examples of using the userid and password default values and not
using the default values:
Examples that do not use the userid and password default values:
asu set SYSTEM_PROD_DATA.SYsInfoProdName asu set SYSTEM_PROD_DATA.SYsInfoSerialNum
asu set SYSTEM_PROD_DATA.SYsEncloseAssetTag

• Remote LAN access, type the command:

Note: When using the remote LAN access method to access IMM using the LAN from a client, the
host and the imm_external_ip address are required parameters.

host [user [[password ]

Where:

imm_external_ip

The external IMM LAN IP address. There is no
default value. This parameter is required.

imm_user_id

The IMM account (1 of 12 accounts). The default
value is USERID.

imm_password

The IMM account password (1 of 12 accounts).
The default value is PASSW0RD (with a zero 0
not an O).

The following commands are examples of using the userid and password default values and not
using the default values:
Examples that do not use the userid and password default values:
asu set SYSTEM_PROD_DATA.SYsInfoProdName host
user password asu set SYSTEM_PROD_DATA.SYsInfoSerialNum host
user password asu set SYSTEM_PROD_DATA.SYsEncloseAssetTag host
user password

Examples that do use the userid and password default values:
asu set SYSTEM_PROD_DATA.SysInfoProdName host asu
set SYSTEM_PROD_DATA.SysInfoSerialNum host asu set
SYSTEM_PROD_DATA.SysEncloseAssetTag host

5. Restart the server.

Completing the FRU replacement

To complete the installation, do the following:

1. If the DIMM air baffle was removed, reinstall it now (see “Removing and installing the DIMM air baffle” on

page 121).

2. Reinstall the cover if it was removed (see “Removing and installing the cover” on page 119).

3. Reinstall the server in the rack cabinet.

4. Reconnect all cables and power cords (see “Connecting the cables” on page 173.

172

Hardware Maintenance Manual