Table 5. DSA Preboot messages (continued)
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 7 “Parts listing, RS210 Types 6531, 6532, 6533, and 6534” on page 175 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a Trained service technician.
• Go to the Lenovo support Web site at
hints, tips, and new device drivers or to submit a request for information.
Message
number
Component Test
State
Description
Action
166-901-xxx IMM
IMM I2C
Test
Failed
The IMM
indicates a
failure in the
H8 bus (Bus
0)
1. Turn off the system and disconnect it from
the power source. You must disconnect the
system from ac power to reset the IMM.
2. After 45 seconds, reconnect the system to the
power source and turn on the system.
3. Run the test again.
4. Make sure that the DSA code is at the latest
level. For the latest level of DSA code, go to
5. Make sure that the IMM firmware is at the latest
level. The installed firmware level is shown in
the DSA event log in the Firmware/VPD section
for this component. For more information, see
“Updating the firmware” on page 211.
6. Run the test again.
7. Remove power from the system.
8. (Trained service technician only) Replace the
system board.
9. Reconnect the system to power and turn on
the system.
10. Run the test again.
11. If the failure remains, go to the Lenovo Web site
for more troubleshooting information at
166-902-xxx IMM
IMM I2C
Test
Failed
The IMM
indicates a
failure in the
memory bus.
1. If the failure remains, go to the Lenovo Web site
for more troubleshooting information at
Chapter 4
.
Diagnostics
81