COMMUNICATOR REPORTING CODES

✦ The 4 by 2 two-digit communicator reporting code

for each event has a factory set value. These values
may be customized to fi t the specifi c installation and
the reporting requirements of the Central Station
monitoring the system.

✦ If Point ID reporting is enabled (the factory default

setting), each sensor can report a unique alarm and
trouble code.

✦ If Point ID is disabled, the “general” reporting codes

for each event type will be used.

✦ Each programming function is performed with

similar keystrokes. After the system is in Setup
Mode, enter the programming step number and
press HOME, then enter the new value and press
AWAY. For reference, follow the fi gures next to the
programming steps.

If the new value is accepted, a “Bing” will sound. If the new

value is not accepted, a “Double Buzz” will sound.

✦ Making a value 0 causes the event not to

communicate to the Central Station.

NOTE: The reporting codes are fi xed for opening

and closing. A unique code is reserved for the
master and the fi ve restricted user codes. See the
Opening & Closing Reporting Codes Table.

GENERAL REPORTING CODES

✦ Use program Steps #201 - 206 to change the

communicator reporting codes when Point ID is
disabled.

✦ Refer to the General Reporting Codes table to view/

edit the reporting codes for each of the fi ve events.
The factory settings are listed, along with a blank
area to write in the new installation values.

STEPS #201-206

Any value from 0-99 can be programmed for each
event using these steps (enter “0” to stop an event
from reporting).

NOTE: Be careful not to duplicate codes unless the

Central Station requires specifi c codes for certain
types of events.

General Reporting Codes Table

GENERAL REPORTING CODES

STEP #

PROGRAMMING FUNCTION

POSSIBLE 4 BY 2 VALUES

FACTORY 4 BY 2 VALUES

INSTALLATION 4 BY 2 VALUE

201

GENERAL FIRE REPORT CODE

0 - 99

1

202

GENERAL EMERGENCY REPORT CODE

0 - 99

2

203

GENERAL SILENT PANIC REPORT CODE

0 - 99

3

204

GENERAL BURGLARY REPORT CODE

0 - 99

4

206

GENERAL TROUBLE REPORT CODE

0 - 99

6

ADEMCO REPORTING CODES

EVENT

ALARM CODE

EXTENDED CODE

SENSOR EMERGENCY

E120

C0xx

CONSOLE EMERGENCY

E120

C026

SENSOR FIRE

E111

C0xx

CONSOLE FIRE

E110

C025

BURGLARY ALARM

E130

C0xx

SILENT PANIC

E122

C0xx

FORCE ARM

E574

C000

DURESS

E121

C000

CANCEL

E406

C000

SENSOR LOW BATTERY

E384

C0xx

SENSOR STATUS TROUBLE

E381

C0xx

CONSOLE LOW BATTERY

E302

C000

CONSOLE BATTERY RESTORE

R302

C000

2-WAY AUDIO

E606

C000

xx = SENSOR NUMBER IN EXTENDED REPORT

HOME

TEST

= PROGRAM

= REMOVE

AWAY

= STORE

0 - 99 FOR GENERAL
ALARM REPORTING CODE

PROGRAMMING STEPS
#201 TO #206

PROGRAM

STORE PROGRAM

2

ABC