beautypg.com

Linear DVS-1200 User Manual

Page 33

background image

31

ADDING ADDITIONAL USER CODES

✦ The Console can be programmed with fi ve restricted

user codes and one page alert user code.

✦ The restricted user codes operate the system as

usual, but cannot access Setup Mode.

✦ The restricted user codes can access a special

Code Mode that can be used to change or remove
any of the fi ve restricted user codes, the page alert
user code, or the duress code.

✦ The page alert user code dials the supervisory

number (programmed for a pager) when it is used
to arm or disarm the system.

✦ A restricted user code is appropriate to give any

user that should be restricted from programming
the Console.

NOTE: For maximum security, a 3-5 digit code is

recommended.

WARNING: NEVER PROGRAM ANY RESTRICTED

USER CODE THE SAME AS THE MASTER USER CODE!

STEPS #93-98

Create any additional user codes using these

steps then log the codes in the boxes to the right.

REMOVING ADDITIONAL USER CODES

STEPS #93-98 Any additional user code can be removed

from the Console by entering the appropriate step
number and pressing TEST.

✦ Because access to programming would be impossible

without a master user code, it cannot be removed
using these steps.

The master user code can be

changed using programming STEP #99.

NOTE: The master user code can be set to the

factory default using the Console master reset
programming step, although all other system
programming will be reset to factory values and all
sensors programmed will be erased.

CONSOLE MASTER RESET

✦ Master resetting the Console will set all of the

programming options back to the factory values. The
master user code will be reset to 1234.

CAUTION: Master resetting the Console will erase the

user codes and remove all programmed sensors. All
Console and communicator programming values will
be reset to the factory defaults.

1.

Start with the system in Test Mode (Setup Mode

cannot be reached from any other mode).

2.

From Test Mode, enter the master user code then

press TEST.

A “Gong” and fi ve “Beeps” will sound, signaling that the

system is in Setup Mode.

3.

Enter programming STEP #999 then press TEST.

4.

Enter 999 again then press TEST again.

A “Bing” will sound to indicate the beginning of the reset

process. This process will take up to 10 seconds while the
memory is being reset.

✦ The system will revert to the fi rst time power-up

condition and the new master user code will be 1234.
Go to the “Basic Console Programming” section of
this manual to begin re-programming the system.

STEP

CODE FUNCTION

CODE ENTERED

STEP #93

RESTRICTED USER CODE #1

STEP #94

RESTRICTED USER CODE #2

STEP #95

RESTRICTED USER CODE #3

STEP #96

RESTRICTED USER CODE #4

STEP #97

RESTRICTED USER CODE #5

STEP #98

PAGE ALERT USER CODE

PROGRAMMING STEPS
#93 TO 98

PROGRAM

STORE PROGRAM

1-5 DIGIT CODE
(3-5 DIGITS RECOMMENDED)

9

WXY

TEST

KEYPAD CODE
PROGRAMMING STEPS
#92 TO 98

REMOVE

START IN TEST

MASTER
USER
CODE

1 GONG &
5 BEEPS

STEP #999
FOR
MASTER
RESET

DONE

PRESS TEST,
1 BING SOUNDS,
WAIT ABOUT 10
SECONDS

TEST

9

WXY

9

WXY

TEST

9

WXY

PRESS
TEST

9

WXY

9

WXY

TEST

9

WXY

ENTER 999
TO OK THE
MASTER
RESET

USE THESE EXACT
KEYSTROKES
TO PERFORM A
MASTER RESET