Communicator programming, Setup mode – Linear DVS-1200 User Manual
Page 34
32
✦ To perform any of the communicator programming
steps, the Console must be in the Setup Mode.
✦ Each programming function is performed with
similar keystrokes. After the Console is in Setup
Mode, enter the programming step number and
press HOME, then enter the new value and press
AWAY. For reference, follow the fi gures next to the
programming steps.
✴ If the new value is accepted, a “Bing” will sound. If the new
value is not accepted, a “Double Buzz” will sound.
SETUP MODE
1. Start with the Console in Test Mode (Setup Mode
cannot be reached from any other mode).
2. From Test Mode, enter the master user code then
press TEST.
✎ NOTE: Only the master user code can be used
to put the Console into the Setup Mode. The
restricted user codes cannot access Setup Mode,
only Code Mode.
✴ A “Gong” and fi ve “Beeps” will sound, signaling that the
system is in Setup Mode.
3. After programming changes are complete, press
the OFF key for three seconds to exit Setup Mode.
✎ NOTE: If the Console is left unattended in Setup
Mode, it will automatically switch back to Off Mode
after three minutes.
13. COMMUNICATOR PROGRAMMING
General Communicator Programming Table
GENERAL COMMUNICATOR OPTIONS
STEP #
PROGRAMMING
FUNCTION
POSSIBLE
VALUES
FACTORY
VALUE
INSTALLATION
VALUE
76
2-WAY AUDIO
0= NONE; 1 = LISTEN; 2 = 2-WAY MANUAL; 3 = 2-WAY FULL DUPLEX
0
78
VOICE RESPONSE FROM KEYPAD SPEAKER
0 = VOICE RESPONSE DISABLED
1 = VOICE RESPONSE ENABLED
0
100
REMOTE PROGRAMMING LOCKOUT
0 = UNLOCK; 1 = LOCK
0
101
CALL LIMITER
0 = OFF; 1 = FIVE CALLS PER ARMING PERIOD
0
103
DIALING DELAY
0 = NO DELAY; 1 = 30 SECOND DELAY
0
104
DIALING METHOD
0 = TONE; 1 = PULSE
0
107
COMMUNICATOR ENABLE
0 = COMMUNICATOR OFF; 1 = COMMUNICATOR ON
0
START IN TEST
MASTER
USER
CODE
1 GONG &
5 BEEPS
TEST
SETUP MODE