AWAY MODE

✦ Use this mode when no one will be staying home.
✦ Each burglary sensor can trigger the siren once per

arming period.

✦ Away Mode causes an instant alarm when any

perimeter sensor is triggered.

✦ Away Mode causes a delayed alarm when any

exit/entry sensor is triggered.

✦ Away Mode causes an instant alarm when any

interior sensors (motion detectors, etc.) are
triggered. The interior sensors will be delayed if a
perimeter delayed sensor is triggered fi rst.

✦ Alarm siren stops automatically after fi ve minutes

and the system will remain armed.

1A. Arm to Away Mode by entering a user code, and

pressing AWAY.

1B. The user can “Quick Arm” to Away Mode from

Home, Chime or Off Mode by pressing AWAY for two
seconds. (Quick arming can be disabled; see the
“Advanced Programming” section of this manual.)

EXIT DELAY (For Leaving the Premises)

When the system is armed to the Away Mode, the Console

will sound a “Gong” and three “Beeps”.

During the 60 second Exit Delay, the Console will sound

“Beeps” (double Beeps last 10 seconds) and the AWAY light
will blink.

2A. The Exit Delay gives the user 60 seconds to

leave the premises through an exit/entry door
without triggering an alarm.

2B. Re-entering during the Exit Delay will extend the

Exit Delay another 60 seconds (one time only).

When the Exit Delay is over, the Console will sound one

“Gong” to warn the user that the system is fully armed.

NOTE: The Exit Delay time can be changed; see the

“Advanced Programming” section of this manual.

ENTRY DELAY (For Entering the Premises)

3A. The Entry Delay gives the user 30 seconds to

enter the premises through an exit/entry door
without triggering an alarm.

3B. If a exit/entry sensor is triggered, starting the

Entry Delay, the interior sensors will also become
delayed (this allows motion in the premises
during the Entry Delay).

During the 30 second Entry Delay, the Console will sound

“Beeps”.

4. When the Entry Delay is over, the Console will

go into full alarm and sound the siren if it is not
disarmed to the Off or Chime Mode.

If an alarm has occurred while the user was gone, multiple

Beeps will sound after disarming and the sensor light for
the sensor(s) that caused the alarm will fl ash (switch to
Off Mode again or re-arm the Console to stop the fl ashing
alarm memory light).

NOTE: The Entry Delay time can be changed; see the

“Advanced Programming” section of this manual.

MANUAL BYPASSING OF SENSORS

✦ Manual bypassing of sensors in the Away Mode

allows arming of the system with open doors and
windows, while still having perimeter protection with
other closed doors and windows.

1. The Console will resist arming with open door or

window sensors.

Four high-low Beeps to warn the user that something is

open and the system will remain in the previous mode.

Lit sensor status indicators show which sensors are open.

2. To manually bypass the open sensors, arm the

system again within fi ve seconds.

A “Gong” and three “Beeps” will sound, the AWAY indicator

will light, and the open sensors will be bypassed.

WARNING: Bypassed sensors cannot cause an

alarm. Closing the sensor removes the bypass.

START HERE

DONE

1 GONG
& 3 BEEPS

HOLD
DOWN

START HERE

YOUR
USER
CODE

DONE

1 GONG
& 3 BEEPS

(OPTIONAL)

AWAY MODE

AWAY

AWAY

QUICK ARM