beautypg.com

Advanced programming, Program = remove, Store – Linear DVS-1200 User Manual

Page 27

background image

25

✦ To perform any of the advanced programming

steps, the Console must be in the Setup Mode.

✦ Each programming function is performed with

similar keystrokes. After the Console is in Setup
Mode, enter the programming step number,
press HOME, then enter the new value and press
AWAY. For reference, follow the fi gures next to the
programming steps.

If the new value is accepted, a “bing” will sound. If the new

value is not accepted, a “double buzz” will sound.

CONSOLE PROGRAMMING OPTIONS

STEP #

PROGRAMMING FUNCTIONS

POSSIBLE VALUES

FACTORY VALUE

INSTALLATION VALUE

25

ENTRY DELAY

20-255 SECONDS

30

26

EXIT DELAY

20-255 SECONDS

60

30

BURGLARY SIREN TIME

1-30 MINUTES

5

31

EMERGENCY SIREN TIME

1-30 MINUTES

5

32

FIRE SIREN TIME

1-30 MINUTES

5

40

AUTOMATION OUTPUT TIME

0-2500 SECONDS (0 = TOGGLE ON/OFF)

0

50

REMOTE ARMING MODE

2 = HOME MODE; 3 = AWAY MODE

3

51

REMOTE DISARMING MODE

0 = OFF MODE; 1 = CHIME MODE

0

61

ENTRY DELAY BEEPS

0 = OFF; 1 = ON

1

62

EXIT DELAY BEEPS

0 = OFF; 1 = ON

1

63

SILENT BURGLARY ALARM

0 = AUDIBLE; 1 = SILENT

0

64

SILENT EMERGENCY ALARM

0 = AUDIBLE; 1 = SILENT

0

65

QUICK ARMING

0 = OFF; 1 = ON

1

66

AUTO RESTORE

0 = OFF; 1 = ON

1

67

AUTO BYPASS

0 = OFF; 1 = ON

0

68

AUTOMATION MODE DURING ALARM

0 = FLASH (ENABLED BY FUNCTION 72)
1 = STEADY (ENABLED BY FUNCTION 72)

0

69

AUTOMATION BING TOME

0 = NO BINGS
1 = BINGS

1

70

REMOTE ARM/DISARM CHIRP

0 = NO CHIRPS
1 = CHIRPS (1 CHIRP = ARMED, 2 CHIRPS = DISARMED)

1

71

AUTOMATION FLASHES AFTER ALARM

0 = STANDARD
1 = FLASHING AFTER ALARM

0

72

AUTOMATION ACTIVE DURING ALARM

0 = STANDARD
1 = AUTOMATION ACTIVE DURING ALARM
(FLASH OR STEADY PROGRAMMED BY FUNCTION 68)

0

73

AUTOMATION ON WHILE ARMED

0 = STANDARD
1 = ON WHILE ARMED

0

74

AUTOMATION ON DURING EXIT/ENTRY

0 = STANDARD
1 = ON DURING EXIT/ENTRY DELAY

0

75

AUTOMATION POLARITY

0 = + WHEN OFF; 1 = + WHEN ON

1

87

REMOTE ACCESS PASSWORD

6 DIGITS

987654

92

DURESS CODE

1-5 DIGITS

REMOVED

93

RESTRICTED USER CODE #1

1-5 DIGITS

REMOVED

94

RESTRICTED USER CODE #2

1-5 DIGITS

REMOVED

95

RESTRICTED USER CODE #3

1-5 DIGITS

REMOVED

96

RESTRICTED USER CODE #4

1-5 DIGITS

REMOVED

97

RESTRICTED USER CODE #5

1-5 DIGITS

REMOVED

98

PAGE ALERT USER CODE

1-5 DIGITS

REMOVED

99

MASTER USER CODE

1-5 DIGITS

1234

SETUP MODE

1. Start with the Console in Test Mode (Setup Mode

cannot be reached from any other mode).

2. From Test Mode, enter the master user code then

press TEST.

NOTE: Only the master user code can be used to

put the system into the Setup Mode. The restricted
user codes cannot access Setup Mode, only Code
Mode.

A “Gong” and fi ve “Beeps” will sound, signaling that the

system is in Setup Mode.

3. After programming changes are complete, press

the OFF key for three seconds to exit Setup Mode.

NOTE: If the system is left unattended in Setup

Mode, it will automatically switch back to Off Mode
after three minutes.

12. ADVANCED PROGRAMMING

HOME

TEST

= PROGRAM

= REMOVE

AWAY

= STORE

Console Programming Table