11

CONSOLE POWER CONNECTION

✦ The Console is powered by a low voltage plug-in

transformer.

✦ Use up to 25 feet of 20 AWG or larger

two-conductor wire to connect the transformer to
the Console.

1. Route the power wires from the plug-in transformer

to the Console.

2. Connect the wires to the transformer terminals (do

not plug the transformer in until the wiring is
complete)
.

3. Route the power wires through the Console's wiring

access hole.

4. Connect the power wires from the transformer

to the Console's main terminal block AC & AC
terminals.

5. Secure all of the wires entering the Console with a

zip-tie to the Console’s strain relief loop.

6. Plug transformer into an unswitched AC outlet.

7. Secure transformer with screw to prevent

unplugging.

BACKUP BATTERY INSTALLATION (OPTIONAL)

✦ A 12-volt backup battery may be installed and is

highly recommended.

✦ The backup battery will power the Console for up to

6 hours during AC power loss.

✦ The backup battery is automatically charged by the

Console when AC power is present.

✦ A low backup battery will cause the Console POWER

indicator to fl ash as it is being charged.

1. To install the battery, slide the battery between the

retaining clamps and under the battery holder.

2. Position the battery until the clamps snap in place.

The battery terminals should be facing the center of
the Console case bottom.

3. Connect the black battery lead to the negative

battery terminal.

4. Connect the red battery lead to the positive battery

terminal.

WARNING: DO NOT REVERSE THE BATTERY

LEADS! THE BATTERY FUSE WILL BLOW.

AC
AC
EXT. SPKR
(-)
H/A -
H/A +
RELAY N.O.
RELAY DRY

MAIN TERMINAL BLOCK

OPTIONAL

VOICE MODULE

MODEL: VB-2

MAIN

TERMINAL

BLOCK

LINEAR SECURITY CONSOLE MODEL DVS-1200

PLUG-IN TRANSFORMER

16 VAC, 28 VA

CONNECT TRANSFORMER LEADS
TO AC POWER TERMINALS

SLIDE BACKUP BATTERY
INTO BATTERY CLAMPS

TRANSFORMER

115 VAC
OUTLET

PLUG TRANSFORMER
INTO 115 VAC OUTLET
THAT IS NOT CONTROLED
BY A LIGHT SWITCH

SCREW

CONNECT RED BATTERY LEAD TO RED TERMINAL
CONNECT BLACK BATTERY LEAD TO BLACK TERMINAL

CAUTION: DO NOT REVERSE BATTERY LEADS

BATTERY FUSE WILL BLOW