Basic console programming – Linear DVS-1200 User Manual
Page 14
12
✦ In a new installation, when power is fi rst applied
the system's master user code is “1234”.
CREATE THE MASTER USER CODE
✎ NOTE: Local programming must be entered on
the Console's keypad, not on a wireless remote
keypad.
1. Press
(clears keypad if any other keys have
been pressed).
2. Place the Console in Test Mode (enter 1234 and
press TEST.
✴ A “gong” and four “beeps” will sound.
3. Enter the Setup Mode from Test Mode, enter 1234
then press TEST again.
✴ A “gong” and fi ve “beeps” will sound. The system is now in
Test Mode.
4. Enter 99 then press HOME.
5. Enter any combination of 1-5 digits for the master
user code, then press AWAY.
✎ NOTE: For maximum security, a three to fi ve digit
code is recommended.
6. Press and hold the OFF key for 3 seconds to exit
program mode.
7. Test the new master user code by entering it then
pressing TEST.
8. Log the master user code in the box below.
✎ NOTE: The master user code can be used to enter
Setup Mode. The restricted user codes cannot. To
create restricted user codes, see the “Advanced
Programming” section of this manual.
PROGRAM THE SENSORS INTO THE CONSOLE’S MEMORY
✦ Each wireless sensor that is going to be used
with the Console must be programmed into the
Console’s memory.
1. Start with the Console in Test Mode (enter any user
code and press TEST).
2. Enter the Setup Mode from Test Mode, enter the
master user code then press TEST again.
✴ A “Gong” and fi ve “Beeps” will sound.
✴ The sensor status indicators will light for any sensors
programmed into the Console.
3. Enter an unused sensor number from 01-12 (you
must enter two digits, example: 5 = 05).
✴ The sensor indicator light will fl ash for the sensor number
selected.
4. Activate the sensor by sending a test or alarm
signal (be sure the sensor's battery is connected or
that its battery protection strip is removed).
✴ A single “Bing” tone will sound and the sensor status
indicator for that sensor will stay lit.
5. Enter another sensor number or exit Setup Mode by
pressing the OFF key for three seconds.
START IN OFF
DEFAULT
MASTER
USER
CODE
1 GONG &
4 BEEPS
(TEST MODE)
START IN SETUP
PROGRAMMING
STEP #99
NEW
MASTER
USER
CODE
DONE
HOLD FOR
3 SECONDS
TO EXIT
SETUP
STORE
CODE
ENTERING
SETUP
MODE
CLEARS
KEYPAD
DEFAULT
MASTER
USER
CODE
1 GONG &
5 BEEPS
(SETUP MODE)
SETTING A
NEW MASTER
USER CODE
PROGRAM
START IN TEST
MASTER
USER
CODE
1 GONG &
5 BEEPS
NEW
SENSOR
NUMBER
ACTIVATE
SENSOR
DONE
TEST
6.
BASIC CONSOLE PROGRAMMING
MASTER USER CODE: