Lucent Technologies MERLIN LEGEND 5 User Manual
Page 244

MERLIN LEGEND Communications System Release 5.0
System Manager’s Guide
555-650-118
Issue 1
June 1997
Managing the System
Page 6-26
Centralized Telephone Programming
6
NOTES:
If you are programming buttons at an extension with an MLX-16DP,
MLX-5D, or MLX-5 telephone, keep the following in mind:
■
The system recognizes the MLX-16DP as an MLX-28D. If you are
replacing an MLX-28D with an MLX-16DP, remove all line and
feature button assignments from the extension
first. This rule also
applies when you are replacing other telephones with an
MLX-16DP.
■
The System Programming Extension Information Report incorrectly
reports MLX-16DP telephones as MLX-28D telephones; keep a
separate log of the MLX-16DP telephones on your system.
■
In releases prior to 5.0, the system recognizes the MLX-5D as an
MLX-10D and the MLX-5 as an MLX-10. If you are replacing an
MLX-5D or an MLX-5 with an MLX-10D or an MLX-10, remove all
line and feature button assignments from the extension
first. This
rule also applies when you are replacing other telephones with an
MLX-5 or MLX-5D.
■
In releases prior to 5.0, the System Programming Extension
Information Report incorrectly reports MLX-5D and MLX-5
telephones as MLX-10D and MLX-10 telephones respectively; keep
a separate log of the MLX-5D and MLX-5 telephones on your
system.
■
In Release 5.0 and later systems, the system recognizes MLX-5 and
MLX-5D telephones as 5-button telephones. The System
Programming Extension Information Report shows the correct
identification for these telephones.
At the Centralized Programming menu, use the following procedure to program
features onto a single telephone. For information about accessing the Centralized
Programming menu, see
‘‘Starting Centralized Telephone Programming’’ on page
.
Console/Display Instructions
Additional Information
PC
Select Program Extension.
Centralized Programming:
Make a selection
Program Ext
Copy Ext
Exit
Enter