Timers

16-Bit Timer Setup Examples

MN102H75K/F75K/85K/F85K LSI User Manual

Panasonic Semiconductor Development Company

109

Panasonic

TM0BR (example)

x’00FE10’

Do not change the clock source
once you select it. Selecting the

clock source while you set up

the count operation control will
corrupt the value in the binary

counter.

3.

Set the TM0LD bit of the TM0MD register to 1. This loads the value in the

base register to the binary counter. At the same time, select the clock source
as B

OSC

/4 by writing b’00’ to TM0S[1:0].

TM0MD (example)

x’00FE20’

In the bank and linear address-

ing versions of the MN102

series, it was necessary to set
TM0EN and TM0LD to 0

between steps 3 and 4, to

ensure stable operation. This is
unnecessary in the high-speed

linear addressing version.

Use the MOV instruction for this

setup and only use 16-bit write

operations.

This step stops the TM4BC

count and clears both TM4BC
and the S-R flip-flop to 0.

4.

Set TM0LD to 0 and TM0EN to 1. This starts the timer. Counting begins at

the start of the next cycle. When the binary counter reaches 0 and loads the
value x’01’ from the base register, in preparation for the next count, a timer 0

underflow interrupt request is sent to the CPU.

To set up timer 4:

1.

Set the operating mode in the timer 4 mode register (TM4MD). Disable

timer 4 counting and interrupts. Select up counting. Set the TM4NLP bit to 0
to select looped counting from 0 to x’FFFF’. Select timer 0 underflow as the

clock source.

TM4MD (example)

x’00FE80’

2.

Set the TM4NLD bit of the TM4MD register to 1 and the TM4EN bit to 0.
This enables TM4BC and the S-R flip-flop. This step ensures stable opera-

tion. If it is omitted, the binary counter may not count the first cycle. Do not
change any other operating modes during this step.

When TM4MD[1:0] = b’11’ (dur-
ing capture), TM4CA and

TM4CB become read-only regis-

ters. To write to TM4CA or
TM4CB, you must first set

TM4MD[1:0] = b’00’.

3.

Set TM4NLD and TM4EN to 1. This starts the timer. Counting begins at the
start of the next cycle.

To enable timer 4 capture B interrupts:

Cancel all existing interrupt requests. Next, set the interrupt priority level in the
TM4CBLV[2:0] bits of the TM4CBICH register (levels 0 to 6), set the TM4BIE

bit to 1, and set the TM4BIR bit of TM4CBICL to 0. From this point on, an
interrupt request is generated whenever a timer 4 capture B event occurs.

Bit:

7

6

5

4

3

2

1

0

TM0

BR7

TM0

BR6

TM0

BR5

TM0

BR4

TM0

BR3

TM0

BR2

TM0

BR1

TM0

BR0

Setting:

0

0

0

0

0

0

0

1

Bit:

7

6

5

4

3

2

1

0

TM0

EN

TM0

LD

TM0

S1

TM0

S0

Setting:

0

1

0

0

0

0

0

0

Bit:

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

TM4

EN

TM4
NLD

TM4
UD1

TM4
UD0

TM4
TGE

TM4
ONE

TM4
MD1

TM4

MD0

TM4

ECLR

TM4

LP

TM4

ASEL

TM4

S2

TM4

S1

TM4

S0

Setting:

0

0

0

0

0

0

0

0

1

1

0

0

1 or 0

0

0

0

This manual is related to the following products: