beautypg.com

Karcher KMR 1550 D User Manual

Page 34

background image

English

KMR 1550 D

34

!

Open cap.

!

Top-up with hydraulic oil.

Oil types: See "Technical Data".

!

Close cap.

!

Check the hydraulic oil level.

!

Tilt the seat back.

Checking and topping up cooling

water

!

Open unit cover.

The cooling water level must be

between the "min." and "max."
marks.

Top up with cooling water if the

cooling water level is below the
"min." mark.

Do not fill up beyond "max.".

!

Open cap

!

Top up cooling water up to the

"max." mark.

!

Close cap.

!

Close unit cover.

Checking cooler hose and hose

clamps

!

Open unit cover.

!

Check whether the hose clamps

are loose, retighten, if necessary.

!

Check cooler hose and hose

clamps for damage.

Note:

If a cooler hose or a hose clamp is

damaged the concerned part must

be immediately repaired or

replaced.

!

Close unit cover.

Check the air cleaner

!

Open unit cover.

!

Open quick-acting clamp.

!

Take off the lid.

!

Take out filter cartridge.

!

Use a new filter cartridge.

!

Place on the sealing cover.

!

Fasten cap with quick-action clamp.

!

Close unit cover.

Check and re-adjust V-belt

The engine takes approx. 3...4 s to

run down after being shut off.
Never enter operating area during

this period!

!

Open unit cover.

In the middle between the

crankshaft and the alternator the V-

belt must yield by approx. 7-9 mm

at a pressure of 100 N (weight of
10 kg).

!

Unscrew screws at the alternator.

!

Adjust alternator so that the V-belt

has the required tension.

!

Retighten the screws at the

alternator.

!

Close unit cover.