Karcher KMR 1550 D User Manual
Page 34

English
KMR 1550 D
34
!
Open cap.
!
Top-up with hydraulic oil.
♦
Oil types: See "Technical Data".
!
Close cap.
!
Check the hydraulic oil level.
!
Tilt the seat back.
Checking and topping up cooling
water
!
Open unit cover.
♦
The cooling water level must be
between the "min." and "max."
marks.
♦
Top up with cooling water if the
cooling water level is below the
"min." mark.
♦
Do not fill up beyond "max.".
!
Open cap
!
Top up cooling water up to the
"max." mark.
!
Close cap.
!
Close unit cover.
Checking cooler hose and hose
clamps
!
Open unit cover.
!
Check whether the hose clamps
are loose, retighten, if necessary.
!
Check cooler hose and hose
clamps for damage.
Note:
•
If a cooler hose or a hose clamp is
damaged the concerned part must
be immediately repaired or
replaced.
!
Close unit cover.
Check the air cleaner
!
Open unit cover.
!
Open quick-acting clamp.
!
Take off the lid.
!
Take out filter cartridge.
!
Use a new filter cartridge.
!
Place on the sealing cover.
!
Fasten cap with quick-action clamp.
!
Close unit cover.
Check and re-adjust V-belt
The engine takes approx. 3...4 s to
run down after being shut off.
Never enter operating area during
this period!
!
Open unit cover.
•
In the middle between the
crankshaft and the alternator the V-
belt must yield by approx. 7-9 mm
at a pressure of 100 N (weight of
10 kg).
!
Unscrew screws at the alternator.
!
Adjust alternator so that the V-belt
has the required tension.
!
Retighten the screws at the
alternator.
!
Close unit cover.