MAINTENANCE INTERVALS
Elapsed-time meter
•
Elapsed-time meter indicates
maintenance interval times.
Maintenance by the customer
Note:
Where maintenance is undertaken by
the customer, all service and
maintenance work must be carried
out by a qualified employee.
KÄRCHER dealer can be called in at
any time if necessary.
Daily maintenance
!
Check the engine oil level.
!
Check roller and side brush for
wear and trapped straps.
!
Clean filter.
!
Check operation of all operating
devices and indicator lights.
Maintenance weekly
!
Check air filter.
!
Check the hydraulic oil level.
Maintenance 50 hours following
initial startup
!
Change the engine oil.
Maintenance every 50 operating
hours
!
For oil change, filling quantity, and
type see Technical Data.
!
Check operation of seat contact
switch.
!
Check voltage, wear, and function
of the drive belt.
!
Check freedom of movement of
Bowden cables and moving parts.
!
Check setting and wear of sealing
strips in sweeping area.
!
Check the tyre air pressure.
!
Check fuel lines and hose clamps.
Maintenance every 100 operating
hours
!
Clean air filter.
!
Replace air filter during every
6. cleaning operation.
!
Checking the battery acid level.
Maintenance 125 hours after initial
startup, then every 75 operating
hours
!
Change the engine oil.
!
Replace oil filter during every 2. oil
change.
Maintenance every 200 operating
hours or every 6 months
!
Check cooler hose and hose
clamps.
Maintenance annually
!
Check the air cleaner.
!
Check dust filter, replace, if
necessary.
Maintenance by the customer
service organisation
Maintenance after 8 operating
hours
First inspection
Maintenance every 100 operating
hours
Maintenance every 400 operating
hours
Maintenance every 500 operating
hours
Maintenance every 800 operating
hours
Maintenance every 2 years
Note:
To ensure the guarantee, all service-
and maintenance work must be
carried out by authorised KÄRCHER
customer service during the
guarantee period..
MAINTENANCE TASKS
Safety instructions
Preparations
!
Stand sweeper on a flat surface.
!
If the motor is operating, stop
motor.
!
Remove the ignition key.
!
Lock the hand brake.
Established deficiencies must be
removed immediately or the vehicle
must be left still.
Opening and closing unit cover
Open unit cover
!
Pull fairing upwards.
!
Unscrew hand screw at the inside
of the unit cover.
!
Tilt unit cover frontwards onto cable
stop.
Close unit cover
!
Tilt back unit cover.
!
Screw hand screw in again.
!
Fold cover in again.