Hardware
50
2120028
Qn
Result Codes
0=Enable result codes (default)
1=Supress result codes
OK(0)
Sn=mm
Sn?
Set register to specified value
Return current value formatted as 3
digit decimal
OK(0)
Varies
Vn
Result Code Format
0=Numerical result codes
1=Verbose result codes (default)
0
OK
Xn
Result Code Format
0=“CONNECT” upon entering
online data state
1-4=“CONNECT
entering online data state
OK(0)
Zn
Load factory default settings
OK(0)
&Cn
DCD Control
0=DCD always on
1=DCD follows connection status
OK(0)
&Dn
DTR Control
0=ignore
1=loss of DTR switches to
command mode and leaves
connection open
2=loss of DTR switches to
command mode and closes
connection (default)
OK(0)
&F
&Fn
Load factory default settings
OK(0)
Equivalent to ATZ without dropping the
connection. This command does not affect the
flash configuration for the port.
&V
&V0
Display S-register values
Example:
E0 Q1 V0 &C1 &D2
S00:002 S02:043 S03:013 S04:010 S05:008
&V1
Status
Returns reason for the last disconnect:
TERMINATION REASON......DTR LOSS
TERMINATION REASON….CARRIER LOSS
&W
&W1
Write current configuration to flash
OK(0)
&Xnnn
Change baud rate.
nnn Baud
3 300
12 1,200
24 2,400
48 4,800
96 9,600
14 14,400
OK(0)
Command
Function
Response