Figure 15, Table 11 – Speed Queen Drying Tumblers none User Manual
Page 42

Steam Requirements
70256801
40
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Figure 15
T221I
NOTE: Refer to Table 11 for sizing of steam lines. Piping must also be sized accordingly for length of runs, and
number of elbows.
1
Supply
8
18 in. (457 mm) Drop
2
12 in. (305 mm) Riser
9
Solenoid Valve (Supplied with machine)
3
Globe Valve
10
Steam Bonnet
4
Return
11
Check Valve
5
Check Valve
12
Union
6
Condensate Return Line from Supply Line
13
Trap with Built-In Strainer
7
Vacuum Breaker
T221I
2
12
11
3
4
1
13
10
9
8
5
6
7
Model
Steam Pressure (psi)
Minimum Pipe Diameter
Steam Trap Size
(Pounds Condensate/
Hour)
CSL
7-15
3/4 in. (19 mm)
140
CSH
80-100
3/4 in. (19 mm)
160
Table 11