25

70256801

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Model 50CG

Table 3

NOTE: Follow all instructions including
verification and adjustment of injector pressure.

1

– Order as Regulated Natural Gas. No modification

needed.

2

– Order as Regulated Natural Gas. Apply

appropriate country sticker.

3

– Order as Regulated Natural Gas. Apply

appropriate country and gas stickers.

4

– Order as Unregulated Natural Gas. Apply

appropriate country sticker.

5

– Order as Unregulated L.P. Gas. Apply appropriate

country sticker.

6

– Order as Regulated Natural Gas. Convert with

regulator spring kit Part No. M411334 and (2) 2.1 mm

injectors Part No. M401003. Apply appropriate

country and gas stickers.

7

Order as Unregulated L.P. Gas. No modification

needed.

8

– Order as Unregulated L.P. Gas. Apply appropriate

country sticker.

OPEN

– No Approval available.

Special Cases

Regulated Gas Valve may be

converted to Unregulated with block-open kit Part No.

M400763.

Gas

Type

GB

IE

PT

ES

IT

DK

NO

SE

FI

DE

NL

BE

FR

AT

Gas

Family &

Group

Inject.

0

Inject. Qty

& Part. No.

Inlet

Press.

Gvnr./

Regltr.

Inject.

Press.

Nat.

Gas

1

1

1

1

1

2

2

2

2

2

2

2nd family

Group H

(E)

3.7 mm

2

M401000

20 mbar

Yes

8.9 mbar

3

2nd family

Group L

(LL)

3.7 mm

2

M401000

25 mbar

Yes

12.6 mbar

4

4

2nd family

Group E+

3.0 mm

2

M401017

20.25

mbar

No

Unreg.

L.P.
Gas

5

5

5

5

5

5

3rd family

Group

B/P

2.1 mm

2

M401003

30 mbar

No

Unreg.

6

6

3rd family

Group

B/P

2.1 mm

2

M401003

50 mbar

Yes

28.5 mbar

7

7

7

7

7

8

8

3rd family

Group 3+

2.1 mm

2

M401033

28.37

mbar

No

Unreg.