Table 5, Installation 27 – Speed Queen Drying Tumblers none User Manual
Page 29

Installation
27
70256801
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Model 75CG
Input: 48.3 kW
Table 5
NOTE: Follow all instructions including
verification and adjustment of injector pressure.
1
– Order as Regulated Natural Gas. No modification
needed.
2
– Order as Regulated Natural Gas. Apply
appropriate country sticker.
3
– Order as Regulated Natural Gas. Apply
appropriate country and gas stickers.
4
– Order as Unregulated Natural Gas. Apply
appropriate country sticker.
5
– Order as Unregulated L.P. Gas. Apply appropriate
country sticker.
6
– Order as Regulated Natural Gas. Convert with
regulator spring kit Part No. M411334 and (3) 2.0 mm
injectors Part No. M400999. Apply appropriate
country and gas stickers.
7
– Order as Unregulated L.P. Gas. No modification
needed.
8
– Order as Unregulated L.P. Gas. Apply appropriate
country sticker.
OPEN
– No Approval available.
Special Cases
– Regulated Gas Valve may be
converted to Unregulated with block-open kit Part No.
M400763.
Gas
Type
GB
IE
PT
ES
IT
DK
NO
SE
FI
DE
NL
BE
FR
AT
Gas
Family &
Group
Inject.
0
Inject. Qty
& Part. No.
Inlet
Press.
Gvnr./
Regltr.
Inject.
Press.
Nat.
Gas
1
1
1
1
1
2
2
2
2
2
2
2nd family
Group H
(E)
3.6 mm
2
M401014
20 mbar
Yes
8.9 mbar
3
2nd family
Group L
(LL)
3.6 mm
2
M401014
25 mbar
Yes
12.6 mbar
4
4
2nd family
Group E+
2.9 mm
2
M402444
20.25
mbar
No
Unreg.
L.P.
Gas
5
5
5
5
5
5
3rd family
Group
B/P
2.0 mm
2
M400999
30 mbar
No
Unreg.
6
6
3rd family
Group
B/P
2.0 mm
2
M400999
50 mbar
Yes
28.5 mbar
7
7
7
7
7
8
8
3rd family
Group 3+
2.0 mm
2
M400999
28.37
mbar
No
Unreg.